Failing Item Code
Description/Action If only a type number is listed, go to the Type, Model, and Part
Number list on page 885 to determine the part number.
FI00702 FI00702 indicates that the local cable for the automatic call unit is the failing item.
Check the automatic call unit interface cable for the part number.
FI00703 FI00703 indicates that the automatic call unit is the failing item.
FI00704 FI00704 indicates that the local data circuit-terminating equipment (DCE) is the failing item.
FI00705 FI00705 indicates that the remote data circuit-terminating equipment (DCE) is the failing
item.
Report this problem to the operator of the remote equipment.
FI00708 FI00708 indicates that the local communications cable (X.21 interface) is the failing item.
Check the communications cable for the part number.
FI00709 FI00709 indicates that the local communications cable (V.35 interface) is the failing item.
Check the communications cable for the part number.
FI00710 FI00710 indicates that the local communications cable (V.24 interface with remote power on)
is the failing item.
The remote power on feature is given support by using an available pin on the
EIA-232/V.24 enhanced or EIA-232/V.24 non-enhanced cables. Check the communications
cable for the part number.
FI00711 FI00711 indicates that the local communications cable (token-ring interface cable) is the
failing item.
Note: An IBM Cabling System Patch Cable or a comparable cable may have been
supplied by the user to increase the length of this cable. Any cable attached to the
token-ring interface cable may also be the failing item.
FI00712 FI00712 indicates that the token-ring access unit is the failing item.
FI00716 FI00716 indicates that the EIA-232/V.24 enhanced cable is the failing item.
Check the communications cable for the part number.
FI00717 FI00717 indicates that the EIA-232/V.24 non-enhanced cable is the failing item.
Check the communications cable for the part number.
FI00718 FI00718 indicates that an IOP card is the failing item.
Use the IOP type to determine the part.
FI00719 FI00719 indicates that an IOA card is the failing item.
FI00720 FI00720 indicates that the Ethernet transceiver is the failing item.
Verify that the signal quality error switch in the transceiver that the Ethernet is attached to
is set to active.
See the transceiver operators guide for correct operation or correct removal and installation
procedure.
FI00721 FI00721 indicates that the token-ring IOA card is the failing item.
Use the IOA type to determine the part.
FI00722 FI00722 indicates that the cable attached to the local area network IOA is the failing item.
Failing Items
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 487

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals