Problem or Message Meaning or Corrective Action
Card type not supported in this slot System code detected a card type that is not
supported in the multi-adapter bridge card
location it is installed in. Move the card to a
location which will support that card type.
Check the installation instructions for the
card to determine which card locations can
support it.
I/O processor removed from multi-adapter
bridge card slot
System code detected that an I/O processor
card was located in that card location on the
previous IPL. The I/O processor is no longer
installed in that location.
I/O adapter unavailable due to moved I/O
processor card
System code detected that the I/O processor
which controlled the I/O adapter card
specified in the DSA has been moved since
the last IPL. The I/O adapter card is
unavailable to the system.
IOA removed from multi-adapter bridge slot System code detected that the card location
specified in the DSA had an I/O adapter
installed on the previous IPL. The I/O
adapter is no longer installed in that card
location.
I/O adapter replaced by I/O processor card System code detected that the card location
specified in the DSA had an I/O adapter
installed on the previous IPL. The I/O
adapter has been replaced by an I/O
processor.
Multi-adapter bridge configuration change
or error
System code has detected a change in the
multi-adapter bridge configuration or a
configuration error since the last IPL.
Symbolic FRUs
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation 553