v Power Supply P02 (dual line cord) – part 21P5383
v Power Supply P03 – part 90H6629
Use the following for FC 5078/0578 and perform “Power PIP8” on
page 394 to isolate the failing item. The failing item may be one of the
following parts:
v Any part on the expansion bus.
v Power Supply P01 – part 21P4970
v Power Supply P02 – part 21P4970
3. Is the SRC 1xxx 1C01, 1C03, 1C05, 1C06, 1C07 or 1C08?
No Yes
↓ Perform “Power PIP7” on page 392 to isolate the failing item. The
failing item may be one of the following parts:
v Any part on the system bus.
v Power Supply PP1 – part 24L0728
v Power Supply PP2 – part 24L0728
4. Is the SRC 1xxx 2201 or 2301?
No Yes
↓ Perform POW– PIP1 in the Migrated Expansion Tower Problem Analysis,
Repair and Parts manual to isolate the failing item. The failing item may
be one of the following parts:
v Any part on the expansion bus.
v Power Supply P01 – part 21H9364
v Power Supply P01 – part 44H7779
v Power Supply P02 – part 44H7779
This ends the procedure.
5. Is the SRC 1xxx 2202 or 2302?
No Yes
↓ Perform POW–PIP2 in the Migrated Expansion Tower Problem Analysis,
Repair and Parts manual to isolate the failing item. The failing item may
be one of the following parts:
v Any part on the expansion bus.
v Power Supply P03 – part 44H7777
v Power Supply P04 – part 44H7777
This ends the procedure.
6. Is the SRC 4414?
Yes No
↓ Go to “Starting Point for All Problems” on page 4.
This ends the procedure.
7. The failing item may be one of the following parts:
v Power Supply P01 (single line cord) – part 90H6629
v Power Supply P01 (dual line cord) – part 21P5383
v Power Supply P02 (single line cord) – part 90H6629
v Power Supply P02 (dual line cord) – part 21P5383
Symbolic FRUs
572
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1