3. Is the SRC 1113 – 111A or 1313 – 131A?
No Yes
↓ Go to “BKSPCN” on page 506 and “BACKPLN” on page 504.
4. Is the SRC 1xxC CE1A?
No Yes
↓ Power regulator R03 is the failing item.
v Expansion I/O tower (FC 5077) – part 21H4829
5. Is the SRC 1xxC 601A, 671A, or 673A?
No Yes
↓ Power regulator 3 is the failing item.
v All Models System Unit – part 23L3603
This ends the procedure.
6. Is the SRC 1xxx 1611, 1612, 1613, 1621, 1622 or 1623?
No Yes
↓ Power regulator 1 or 2 is the failing item. The failing item is in Card
Position M01 – part 24L0965 or 24L0964.
This ends the procedure.
7. Is the SRC 1xxx 1631, 1632, or 1633?
No Yes
↓ Power regulator 3 is the failing item. The failing item is in Card
Position M06 – part 23L7461.
This ends the procedure.
8. Is the SRC 1xxx 6018, 6118, 6518, 6818, 6918, 601A or CE18?
No Yes
↓ Power regulator 1, 2, or 3 is the failing item.
Perform ″SPCN-PIP1″ in Migrated Expansion Tower Problem Analysis,
Repair and Parts to determine the failing item.
The following list shows the possible failing items:
v System Unit Expansion (FC 507x) – part 87G6049
v Storage Expansion Tower (FC 508x) – part 17G1209
v Expansion I/O tower (FC 5077) – part 21H4829
This ends the procedure.
9. Is the SRC 1xxx 6x18 or 6x1A?
No Yes
↓ Power regulator 1 is the failing item.
Perform ″SPCN-PIP1″ in Migrated Expansion Tower Problem Analysis,
Repair and Parts to determine the failing item.
The following list shows the possible failing items:
v System Unit Expansion (FC 507x) – part 87G6049
v Storage Expansion Tower (FC 508x) – part 17G1209
Symbolic FRUs
574
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1