Table 45. FRU Locations and Failing Components Table for FC 5075 I/O Towers
Position FRU Name Possible
Failing
Component
Type, CCIN, or Part Number
(use the “Type, Model, and
Part Number list” on
page 885 to determine the
part number when Type or
CCIN are given.)
Removal and Installation Procedure
C01 PCI Card IOA See “Type, Model, and Part
Number list” on page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C02 PCI Card The failing
component is
either an:
1. Integrated
xSeries
Server
(IXS)
2. IOP
3. IOA
1. 2890
2. 2842 or 2843
3. See “Type, Model, and
Part Number list” on
page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C03 PCI Card (if
no IXS in
C02)
The failing
component is
either an:
1. IOP
2. IOA
1. 2842 or 2843
2. See “Type, Model, and
Part Number list” on
page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C04 PCI Card The failing
component is
either an:
1. IOP
2. IOA
1. 2842 or 2843
2. See “Type, Model, and
Part Number list” on
page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C05 PCI Card The failing
component is
either an:
1. Integrated
xSeries
Server
(IXS)
2. IOP
1. 2890
2. 2842 or 2843
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C06 PCI Card (if
no IXS in
C05)
The failing
component is
either an:
1. IOP
2. IOA
1. 2842 or 2843
2. See “Type, Model, and
Part Number list” on
page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C07 PCI Card The failing
component is
either an:
1. IOP
2. IOA
1. 2842 or 2843
2. See “Type, Model, and
Part Number list” on
page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
C08 PCI Card IOA See “Type, Model, and Part
Number list” on page 885.
Go to “FC 5075 – Cards –
Concurrent” on page 638.
Locations and Addresses