Notes:
1. If the failing item is a failing item (FI) code, go to Failing Items on page 479
to determine which part number associated with the FI code is failing.
2. If the failing item is a type number, go to Type, Model, and Part Number list
on page 885 to determine the part number.
3. If the failing item is a symbolic FRU, go to Symbolic FRUs on page 495 to
determine the part number.
Reference Code Description/Action Perform all actions before exchanging Failing Items Failing Item
00A0 SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
TWRCARD
00A1 Regulator 1 has been turned off by system
No action required. This reference code is logged for information only.
00A2 Regulator 2 has been turned off by system
No action required. This reference code is logged for information only.
00A3 Regulator 3 has been turned off by system
No action required. This reference code is logged for information only.
00A4 Regulator 4 has been turned off by system
No action required. This reference code is logged for information only.
00A5 Regulator 5 has been turned off by system
No action required. This reference code is logged for information only.
00A6 Regulator 6 has been turned off by system
No action required. This reference code is logged for information only.
00A7 The system is running on the Battery Power Unit.
No action required. This reference code is logged for information only.
00A8 The Battery Power Unit is not fully charged.
No action required. This reference code is logged for information only.
00A9 Battery Power Unit test is in process.
No action required. This reference code is logged for information only.
00AA Download in process
No action required. This reference code is logged for information only.
00AB Rack UEPO switch is OFF.
Informational reference code.
The UEPO switch must be returned to the On position to power on the
rack.
TWRCARD
CTLPNL
6462417
00AC Detected AC loss
If system powers on normally or stays powered on after AC power failure,
no replacement of parts may be needed.
ACMODUL
1xxx
Chapter 2. Unit Reference Codes 65