Systems that have remote load source mirror protection can be
recovered by using the steps in Recover Remote Load Source on
page 917.
If you do know if this system has remote load source mirror protection,
contact your next level of support.
b. Select the Work with disk units option on the Service Tools display.
c. Select the Display disk configuration option.
d. Select the Display disk configuration status option.
Does the failing disk unit have a status of Suspended?
No Yes
Go to step 15 of this procedure.
2. Does the disk unit that is mirrored to the failing disk unit have a status of
Suspended?
Yes No
Go to step 12 of this procedure.
3. Is the failing disk unit the load source (disk unit 1)?
Yes No
Ask the customer to end all applications that are running on the
system and power the system off with the Power Down System
(PWRDWNSYS) command.
To save the data by copying to tape:
v Go to Disk Unit Data Save and Initialize on page 903.
To save the data by copying to another disk:
v Go to Disk Unit Initialize and Disk to Disk Copy on page 912.
4. Is the failing load source disk unit a local load source?
No Yes
Ask the customer to end all applications that are running on the
system and power the system off with the Power Down System
(PWRDWNSYS) command.
To save the data by copying to tape:
v Go to Disk Unit Data Save and Initialize on page 903.
To save the data by copying to another disk:
v Go to Disk Unit Initialize and Disk to Disk Copy on page 912.
5. You are at this step because the remote load source is failing and the local
load source has a state of Suspended.
Perform the following to attempt to repair the local load source. Doing this
procedure reduces the duration of the repair time.
a. Record the location of the local load source disk unit.
b. Exchange the local load source disk unit using concurrent maintenance for
the model or FC that you are working on (seeChapter 4. Removal and
Installation Procedures on page 617).
Data Recovery and General System Information
898
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM i 830 and is the answer not in the manual?

IBM i 830 Specifications

General IconGeneral
BrandIBM
Modeli 830
CategoryServer
LanguageEnglish

Related product manuals