status of the other rows to see if there are any failed links, other than the
links that you recorded for the tower that you are working on.
Are there any other failed links that are not associated with the tower that you
are working on?
Yes No
Go to step 12 of this procedure.
11. Using table Appendix F. HSL Loop Configuration and Status Form on
page 963, look to see if there are any operational links between this tower and a
failed link.
Are there any such operational links?
No Yes
You can not use this procedure to power off the tower. Doing so will
cause resources to be lost and a possible system failure. You must
power down the system to continue working on this tower (see
Powering On and Powering Off the System and Logical Partitions
on page 922).
This ends the procedure.
12. Examine table Appendix F. HSL Loop Configuration and Status Form on
page 963, to determine if the tower that you are working on is linked to an
SPD migrated tower (FC 5033, 5034, 5035, or 5077).
Is an SPD migrated tower (FC 5033, 5034, 5035, or 5077), the next link
(leading or trailing) from the tower that you are working on?
No Yes
You can not use this procedure to power off the tower. Doing so will
cause a system failure. You must power down the system to continue
working on this tower (see Powering On and Powering Off the
System and Logical Partitions on page 922).
This ends the procedure.
13. Are you working in a FC 5079 expansion tower or unit?
No Yes
Power off only the expansion tower or unit (FC 5074) that you are
servicing.
Attention: Only one expansion tower inside the 1.8 meter rack may
be powered off at any given time!
Continue with step 14 of this procedure.
14. Were you directed to power off the tower to set the SPCN configuration ID?
No Yes
Go to step 17 on page 930 of this procedure.
15. Verify that the type numbers (ie; IOPs, IOAs, etc.) contained in the
expansion tower or unit that you are powering off, matches what is shown on
the system by performing the following:
a. From the SST or DST menu, select the Start a service tool option.
b. Select the Hardware service manager option.
c. Select the Packaging Hardware Resources (systems, frames, cards, etc.) option.
Data Recovery and General System Information
Chapter 6. Data Recovery Procedures and General System Information 929