d. Are you working in the Primary partition?
No Yes
Perform the function 69 (with the control panel set to Manual
Mode) from the control panel (See Control Panel Functions in
the iSeries Service Functions information). Then, go to step 29 of this
procedure.
e. Perform function 69 from the Work with partition status screen in the
Primary partition. Then, go to step 29 of this procedure.
f. If the Packaging Hardware Resources display is available, specify the Power
on option for the expansion tower or unit you were working on and press
the Enter key.
g. If the Packaging Hardware Resources display is not available, select (with
the control panel set to Manual Mode) the SPCN control panel function to
power on the expansion tower or unit.
Note: See Control Panel Functions in the iSeries Service Functions
information.
1) Select function 07 and press enter.
2) Increment to 01 and press enter.
This will send out a Rack Power On command on the SPCN Network
which will restore power to the expansion tower or unit, which has
become powered off.
29. From the Packaging Hardware Resources display, select the Associated Logical
Resource(s) option for the expansion tower or unit.
The Logical Hardware Resources Associated a Packaging Resource display
shows the status of devices and IOPs.
30. When all expected resources appear with an operational status, work with the
customer to bring the system to the operational state.
Note: For V4R3 and following (more recent) releases, a resource that has been
removed will show a status of Not Connected. For earlier systems the
status will show as Disabled.
Work with the customer to restart all bus activity:
v Start all subsystems that were ended.
v Vary on all devices, lines, and controllers for the expansion tower or unit
that was powered off.
v Start customer applications.
31. Was the tower configured as a switchable tower under iSeries 400
OptiConnect for HSL when you entered this procedure?
Yes No
If you moved the AC power cords of an expansion unit from this
tower to an alternate AC power source during this procedure, then
move them back to this expansion tower. Move only one of the
expansion units AC power cords at a time to this tower, to prevent
the expansion unit from loosing AC power.
This ends the procedure.
32. Did you change the towers mode to Private using HSM?
No Yes
Data Recovery and General System Information
Chapter 6. Data Recovery Procedures and General System Information 933