EasyManua.ls Logo

iXBlue GAPS - Page 171

iXBlue GAPS
232 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GAPS - User Guide
E Settings Examples
E.1 One Transponder
TP Interr. code Reply code TaT Rep. factor
TP1 1 22 90 ms x1
Distance max (m) < 682 < 1432 < 2182 < 2932 < 3682 < 4432
Recurrence 1 s 2 s 3 s 4 s 5 s 6 s
Blanking time TP1 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
E.2 Two Transponders - Same Interrogation Code
TP Interr.code Reply code TaT Rep. factor
TP1 1 22 90 ms x1
TP2 1 23 90 ms x1
Distance max (m) < 682 < 1432 < 2182 < 2932 < 3682 < 4432
GAPS recurrence 1 s 2 s 3 s 4 s 5 s 6 s
Blanking time TP1 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
Blanking time TP2 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
MU-GAPS-AN-005-H - November 2019 171