GAPS - User Guide
E Settings Examples
E.1 One Transponder
TP Interr. code Reply code TaT Rep. factor
TP1 1 22 90 ms x1
Distance max (m) < 682 < 1432 < 2182 < 2932 < 3682 < 4432
Recurrence 1 s 2 s 3 s 4 s 5 s 6 s
Blanking time TP1 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
E.2 Two Transponders - Same Interrogation Code
TP Interr.code Reply code TaT Rep. factor
TP1 1 22 90 ms x1
TP2 1 23 90 ms x1
Distance max (m) < 682 < 1432 < 2182 < 2932 < 3682 < 4432
GAPS recurrence 1 s 2 s 3 s 4 s 5 s 6 s
Blanking time TP1 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
Blanking time TP2 0.8 s 1.8 s 2.8 s 3.8 s 4.8 s 5.8 s
MU-GAPS-AN-005-H - November 2019 171