E.3 Two Transponders - Two Interrogation Codes
TP Interr. code Reply code TaT Rep. factor
TP1 1 22 90 ms x1
TP2 2 22 90 ms x1
Distance max (m) < 682 < 1432 < 2182 < 2932 < 3682 < 4432
GAPS recurrence 1 s 2 s 3 s 4 s 5 s 6 s
Blanking time TP1 1.8 s 3.8 s 5.8 s 7.8 s 9.8 s 11.8 s
Blanking time TP2 1.8 s 3.8 s 5.8 s 7.8 s 9.8 s 11.8 s