Appendix D
Common commands
In this appendix:
Command summary ................................................................ D-1
Script command equivalents ................................................... D-2
Command reference ................................................................ D-2
Command summary
Common commands supported by the Model 2651A are summarized in the following table. Although
commands are shown in upper-case, common commands are not case sensitive, and either upper or
lower case can be used. Note that although these commands are essentially the same as those
defined by the IEEE- 488.2 standard, the Model 2651A does not strictly adhere to that standard.
NOTE
Unlike other commands, such as those in the Command reference (on page 7-1), each common
command must be sent as separate lines.
Mnemonic Name Description
*CLS Clear status Clears all event registers and Error Queue. For status commands
details, see Status model
(on page E-1).
*ESE <mask> Event enable command Program the Standard Event Status Enable Register. For status
commands details, see Status model
(on page E-1).
*ESE? Event enable query Read the Standard event status enable Register. For status
commands details, see Status model
(on page E-1).
*ESR? Event status register query Read/clear the Standard Event Enable Register. For status
commands details, see Status model
(on page E-1).
*IDN? Identification query Returns the manufacturer, model number, serial number, and
firmware revision levels of the unit. For detailed information, see
Identification query: *IDN?
(on page D-3).
*OPC Operation complete command Set the Operation Complete bit in the Standard Event Register
after all pending commands have completed. For detailed
information, see Operation complete and query: *OPC and *OPC?
(on page D-3).
*OPC? Operation complete query Places an ASCII "1" into the Output Queue when all selected
device operations have completed. For detailed information, see
Operation complete and query: *OPC and *OPC?
(on page D-3).
*RST Reset command Returns the Model 2651A to default conditions. For detailed
information, see Reset: *RST
(on page D-3).
*SRE <mask> Service request enable command Programs the Service Request Enable Register. For status
commands details, see Status model
(on page E-1).
*SRE? Service request enable query Reads the Service Request Enable Register. For status
commands details, see Status model
(on page E-1).
*STB? Status byte query Reads the status byte register. For status commands details, see
Status model
(on page E-1).

Table of Contents

Other manuals for Keithley 2651A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2651A and is the answer not in the manual?

Keithley 2651A Specifications

General IconGeneral
BrandKeithley
Model2651A
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals