FlexLine plus, Technical Data
167
17 Technical Data
17.1 Angle Measurement
Accuracy
Characteristics Absolute, continuous, diametric. Updates each 0.1 to 0.3 s.
17.2 Distance Measurement with Reflectors
Range
Atmospheric
conditions
Available angular
accuracies
Standard deviation
Hz, V, ISO 17123-3
Display resolution
["] [mgon] ["] [°] [mgon] [mil]
1 0.3 0.1 0.0001 0.1 0.01
2 0.6 0.1 0.0001 0.1 0.01
3 1.0 0.1 0.0001 0.1 0.01
5 1.5 0.1 0.0001 0.1 0.01
7 2 0.1 0.0001 0.1 0.01
Reflector Range A Range B Range C
[m] [ft] [m] [ft] [m] [ft]
Standard prism (GPR1) 1800 6000 3000 10000 3500 12000
3 prisms (GPR1)
2300 7500 3000 10000 3500 12000
2300 7500 4500 14700 5400 17700
360° prism (GRZ4, GRZ122) 800 2600 1500 5000 2000 7000
Reflector tape 60 mm x 60 mm
Prism mode 150 500 250 800 250 800
Non-prism mode, R500 300 1000 500 1600 >500 >1600
Non-prism mode, R1000 600 1950 1000 3300 >1000 >3300
Mini prism (GMP101) 800 2600 1200 4000 2000 7000
360° Mini prism (GRZ101) 450 1500 800 2600 1000 3300
Shortest measuring distance: 1.5 m
Range A: Strong haze, visibility 5 km; or strong sunlight, severe heat shimmer
Range B: Light haze, visibility about 20 km; or moderate sunlight, slight heat
shimmer
Range C: Overcast, no haze, visibility about 40 km; no heat shimmer