FlexLine plus, Operation
36
Change the
intensity of the
laser plummet
External influences and the surface conditions may require the adjustment of the
intensity of the laser plummet.
Position over pipes
or holes
5. Centre the electronic level for the second
axis by turning the last footscrew. An arrow
shows the direction of rotation required.
When all three bubbles are centred,
the instrument has been perfectly
levelled up.
6. Accept with Cont.
In the Level & Plummet screen, adjust the
intensity of the laser plummet using the
navigation key.
The laser can be adjusted in 20% steps as
required.
Under some circumstances the laser dot is
not visible, for example over pipes. In this
case, using a transparent plate enables the
laser dot to be seen and then easily aligned
to the centre of the pipe.