276
The following values are possible:
1. Output : Enable the 1 pps clock output
2. Input : Enable the 1 pps clock input
3. Disable : Disable the 1 pps clock in/out-put
External Enable
This Selection box will allow you to configure the External Clock output.
The following values are possible:
1. True : Enable the external clock output
2. False : Disable the external clock output
Adjust Method
This Selection box will allow you to configure the Frequency adjustment configuration.
1. LTC frequency : Select Local Time Counter (LTC) frequency control
2. SyncE-DPLL : Select SyncE DPLL frequency control, if allowed by SyncE
3. Oscillator : Select an oscillator independent of SyncE for frequency control, if supported
by the HW
4. LTC phase : Select Local Time Counter (LTC) phase control (assumes that the frequency
is locked by means of SyncE)
Clock Frequency
This will allow to set the Clock Frequency.
The possible range of values are 1 - 25000000 (1 - 25MHz)
PTP Clock Configuration
Delete
Check this box and click on 'Save' to delete the clock instance.
Inst
Indicates the Instance of a particular Clock Instance [0..3].