322
Displays the measured coupled TX output power in mW. Accuracy is vendor specific
but must be better than 3dB over specified operating temperature and voltage.
Data is assumed to be based on measurement of a laser monitor photodiode
current. Data is not valid when the transmitter is disabled.
Mon3 (RX PWR)
Displays the measured received optical power in mW. Absolute accuracy is
dependent upon the exact optical wavelength. For the vendor specified wavelength,
accuracy should be better than 3dB over specified temperature and voltage. This
accuracy should be maintained for input power levels up to the lesser of maximum
transmitted or maximum received optical power per the appropriate standard. It
should be maintained down to the minimum transmitted power minus cable plant
loss (insertion loss or passive loss) per the appropriate standard. Absolute accuracy
beyond this minimum required received input optical power range is vendor
specific.
Buttons
Auto-refresh: Check this box to refresh the page automatically. Automatic refresh
occurs every 3 seconds.
Clear: Clears the counters for the selected port.
Refresh: Click to refresh the page.
3-4 Link OAM
3-4.1 Statistics
This page provides detailed OAM traffic statistics for a specific switch port. Use the port
select box to select which switch port details to display.
The displayed counters represent the total number of OAM frames received and
transmitted for the selected port. Discontinuities of these counter can occur at
re-initialization of the management system.