EasyManuals Logo

LSIS SV-IS7 User Manual

LSIS SV-IS7
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #174 background imageLoading...
Page #174 background image
Table of Functions
Function
Table
163
Expansion Function Group (PAR ADV)
No.
Communi-
cation
Address
LCD
Display
Name
Setting Range
Initial
Value
Shift in
Opera-
tion
Control Mode
V
/
F
S
L
V
C
S
L
T
V
C
T
24
0h1318
Freq Limit
Frequency limit
0
No
0:No
X
O
O
O
X
X
1
Yes
25
Note
10
)
0h1319
Freq Limit
Lo
Frequency lower limit
0
upper limit (Hz)
0.50
O
O
O
O
X
X
26
0h131A
Freq Limit
Hi
Frequency upper limit
0.5
maximum frequency
(Hz)
60.00
X
O
O
O
X
X
27
0h131B
Jump Freq
Frequency jump
0
No
0:No
X
O
O
O
X
X
1
Yes
28
Note
11
)
0h131C
Jump Lo 1
Jump frequency lower
limit 1
0
jump frequency upper
limit 1 (Hz)
10.00
O
O
O
O
X
X
29
0h131D
Jump Hi 1
Jump frequency upper
limit 1
Jump frequency lower limit
1
maximum frequency (Hz)
15.00
O
O
O
O
X
X
30
0h131E
Jump Lo 2
Jump frequency lower
limit 2
0
jump frequency
upper limit 2 (Hz)
20.00
O
O
O
O
X
X
31
0h131F
Jump Hi 2
Jump frequency upper
limit 2
Jump frequency lower limit
2
maximum frequency (Hz)
25.00
O
O
O
O
X
X
32
0h1320
Jump Lo 3
Jump frequency lower
limit 3
0-jump frequency
upper limit 3 (Hz)
30.00
O
O
O
O
X
X
33
0h1321
Jump Hi 3
Jump frequency upper
limit 3
Jump frequency lower limit
3
maximum frequency (Hz)
35.00
O
O
O
O
X
X
34
Note
10
)
0h1322
Jog Freq
Limit
Jog frequency limit
0
No
1:Yes
O
O
O
O
X
X
1
Yes
41
Note
12
)
0h1329
BR Rls Curr
Brake release current
0
180.0 (%)
50.0
O
O
O
O
X
X
42
0h132A
BR Rls Dly
Brake release delay
time
0
10.00 (sec)
1.00
X
O
O
O
X
X
44
0h132C
BR Rls Fwd
Fr
Brake release
forward frequency
0
400 (Hz)
1.00
X
O
O
O
X
X
45
0h132D
BR Rls Rev
Fr
Brake release
reverse frequency
0
400 (Hz)
1.00
X
O
O
O
X
X
46
0h132E
BR Eng Dly
Brake engage delay
time
0
10 (sec)
1.00
X
O
O
O
X
X
47
0h132F
BR Eng Fr
Brake engage
frequency
0
400 (Hz)
2.00
X
O
O
O
X
X
50
0h1332
E-Save
Mode
Energy saving
operation
0
None
0:None
X
O
O
X
X
X
1
Manual
2
Auto
51
Note
13
)
0h1333
Energy
Save
Energy saving amount
0
30 (%)
0
O
O
O
O
X
X
60
0h133C
Xcel
Change Fr
Acc/dec time
transition frequency
0
maximum frequency (Hz)
0.00
X
O
O
O
X
X
* The grey cells indicate a hidden code which is only visible when setting a code.
Note 10)
ADV-25
26, 34 is displayed only when ADV-24 (Freq Limit) is set asFreq Limit”.
Note 11)
ADV-28
33 is displayed only when ADV-27 (Jump Freq) is set asYes”.
Note 12)
ADV-41
47 is displayed only when a code of OUT-31
33 is set as BR Control”.
Note 13)
ADV-51 is displayed only when ADV-50 (E-Save Mode) is set as a value other thanNone”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS SV-IS7 and is the answer not in the manual?

LSIS SV-IS7 Specifications

General IconGeneral
BrandLSIS
ModelSV-IS7
CategoryInverter
LanguageEnglish