Peripheral Devices
Peripheral
Devices
207
9.1.3
Dynamic Braking Unit (DBU) and Resistor
Dynamic Braking Unit Specifications
UL form
Type
Voltage
Capacity of
applied motor
Braking unit
Reference-
Terminal
arrangement &
dimensions
UL type
Type A
(For resistance of
DB resistors,
refer to 9.1.6 DB
Resistors on page
217.)
200 V
3037 kW
SV370DBU-2U
Group 1
4555 kW
SV550DBU-2U
75 kW
SV370DBU-2U, 2Set
400 V
3037 kW
SV370DBU-4U
4555 kW
SV550DBU-4U
75 kW
SV750DBU-4U
90 kW
SV550DBU-4U, 2Set
110132 kW
SV750DBU-4U, 2Set
160 kW
SV750DBU-4U, 3Set
Non UL
type
Type B
(For resistance of
DB resistors,
refer to the DB
Unit manual)
200 V
3037 kW
SV037DBH-2
Group 2
400 V
3037 kW
SV037DBH-4
4555 kW,
75 kW
SV075DBH-4
SV075DB-4
Group 3
185220 kW
SV2200DB-4 Note 1)
Group 4
280375 Kw
SV2200DB-4, 2Set
Type C
(For resistance of
DB resistors,
refer to the DB
Unit manual)
200 V
3037 kW
LSLV0370DBU-2LN
Group 5
LSLV0370DBU-2HN
Group 6
4555 kW,
75 kW
LSLV0750DBU-2LN
Group 5
LSLV0750DBU-2HN
Group 6
400 V
3037 kW
LSLV0370DBU-4LN
Group 5
LSLV0370DBU-4HN
Group 6
4555 kW,
75 kW
LSLV0750DBU-4LN
Group 5
90 kW
LSLV0900DBU-4HN
Group 6

Table of Contents