Page #199 background imageLoading...
Page #199 background image
188
No.
Communi-
cation
Address
LCD Display
Name
Setting Range
Initial
Value
Shift in
Opera-
tion
Control Mode
V
/
F
S
L
V
C
S
L
T
V
C
T
frequency (Hz)
60
0h193C
Seq 2/5 XcelT
2/5 Acc/Dec time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
61
0h193D
Seq 2/5
SteadT
2/5 steady speed
operation time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
62
0h193E
Seq 2/5 Dir
2/5 operation direction
0
Reverse
1:Forward
O
O
O
O
X
X
1
Forward
63
0h193F
Seq 2/6 Freq
2/6 step frequency
0.01
maximum
frequency (Hz)
60.00
O
O
O
O
X
X
64
0h1940
Seq 2/6 XcelT
2/6 Acc/Dec time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
65
0h1941
Seq 2/6
SteadT
2/6 steady speed
operation time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
66
0h1942
Seq 2/6 Dir
2/6 operation direction
0
Reverse
1:Forward
O
O
O
O
X
X
1
Forward
67
0h1943
Seq 2/7 Freq
2/7 step frequency
0.01
maximum
frequency (Hz)
52.00
O
O
O
O
X
X
68
0h1944
Seq 2/7 XcelT
2/7 Acc/Dec time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
69
0h1945
Seq 2/7
SteadT
2/7 steady speed
operation time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
70
0h1946
Seq 2/7 Dir
2/8 operation direction
0
Reverse
1:Forward
O
O
O
O
X
X
1
Forward
71
0h1947
Seq 2/8 Freq
2/8 step frequency
0.01
maximum
frequency (Hz)
22.00
O
O
O
O
X
X
72
0h1948
Seq 2/8 XcelT
2/8 Acc/Dec time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
73
0h1949
Seq 2/8
SteadT
2/8 steady speed
operation time
0.1
600.0 (sec)
5.0
O
O
O
O
X
X
74
0h194A
Seq 2/8 Dir
2/8 operation direction
0
Reverse
1:Forward
O
O
O
O
X
X
1
Forward
* The grey cells indicate a hidden code which is only visible when setting a code.
Note 32)
AUT group is displayed only when APP-01(App Mode) is set asAuto Sequence”.
Note 33)
AUT-04 codes are displayed only when AUT-03 Seq Select) is set as 1”.
Note 34)
AUT-05 codes are displayed only when AUT-03 (Seq Select) is set as2”.
Note 35)
AUT-10
41 codes are displayed only when AUT-03 (Seq Select) is set as1”.
Note 36)
AUT-43
74 codes are displayed only when AUT-03 (Seq Select) is set as2”.