EXAMPLE: (Routine homes motor against a hard stop)
MDS 'Using Sine mode commutation
KP=3200 'Increase stiffness from default
KD=10200 'Increase damping from default
F 'Activate new tuning parameters
AMPS=100 'Lower current limit to 10%
VT=-10000 'Set maximum velocity
ADT=100 'Set maximum accel/decel
MV 'Set Velocity mode
G 'Start motion
WHILE EA>-100 'Loop while position error is small
LOOP 'Loop back to WHILE
O=-100 'While pressed, declare home offset
S 'Abruptly stop trajectory
MP 'Switch to Position mode
VT=20000 'Set higher maximum velocity
PT=0 'Set target position to be home
G 'Start motion
TWAIT 'Wait for motion to complete
AMPS=1023 'Restore current limit to maximum
END 'End program
RELATED COMMANDS:
R
AT=formula Acceleration Target (see page 280)
R
DT=formula Deceleration Target (see page 390)
R
EL=formula Error Limit (see page 419)
G Start Motion (GO) (see page 456)
MP Mode Position (see page 582)
MV Mode Velocity (see page 593)
PID# Proportional-Integral-Differential Filter Rate (see page 623)
R
PRT=formula Position, Relative Target (see page 652)
R
PT=formula Position, (Absolute) Target (see page 658)
R
VT=formula Velocity Target (see page 788)
X Decelerate to Stop (see page 804)
Part 2: Commands: ADT=formula

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog SmartMotor and is the answer not in the manual?

Moog SmartMotor Specifications

General IconGeneral
BrandMoog
ModelSmartMotor
CategoryServo Drives
LanguageEnglish

Related product manuals