Electa Elite Issue 6
Features and Specifications Manual I - 21
Data Assignments for Calling Party Number (CPN) Presentation from
Station:
Use Memory Block 4-47 (ISDN Directory Number Selection) to
specify whether or not the station is allowed to present the assigned
number in Memory Block 4-62 to the network for Caller ID
information when trunks are assigned as DID in Memory Block 3-91.
System Software S6000 or higher and PRT Firmware 3.50 or
higher are required.
Use Memory Block 4-62 (ISDN-PRI Directory Number Selection) to
provide individual stations with the 10-digit number to be presented
to the ISDN Network when trunks are assigned as DID in Memory
Block 3-91. User provided Call screening and presentation may or
may not be needed from the ISDN provider. System Software
S6000 or higher and PRT Firmware 3.50 or higher are required.
Restrictions:
The ISDN-PRI interface provides voice communication only.
The Electra Elite system does not support Multipoint Access.
MIFM-U10 Software 2.00 or higher and LCR PC Software 2.00 or
higher are required to program Call by CAll LCR assignments.
Restrictions for Calling Party Name and Calling Party Number
Presentation from Station:
The Electra Elite supports receiving the name from the Network in
supported formats only and cannot Send The Calling Name. Refer
To Supported Protocols And Name Delivery Formats table.
Redirecting Name is not supported by the Electra Elite. Redirecting
Name (originally called name and last redirecting name) is sent when
an incoming call is forwarded from another Telco or System.
The Electra Elite can only display 13 characters of the provided
Name or Number from the ISDN Network.
The Electra Elite does not display the name presentation status as
private or unavailable.
When Memory block 4-47 is assigned as YES, and Memory BLock
4-62 has a number assigned, the setting in Memory Block 4-62
overrides the number set in Memory Block 3-52 when the station
places an outgoing call using PRI. System Software S6000 or
higher and PRT Firmware 3.50 or higher are required.
PRT trunk types must be assigned as DID in Memory Block 3-91 for
Memory Block 4-62 to provide the number to the ISDN Network.
System Software S6000 or higher is required.