M - 10 Multiline Conference Bridge
Issue 6 Electra Elite
Use Memory Block 4-14 (Intercom Master Hunt Number Selection) to
assign (YS) a master intercom number to each telephone. All ports
that are set to the same conference group should be set to the same
Master Hunt Group. Default is NO (unassigned).
Use Memory Block 4-15 (Intercom Master Hunt Number Forward
Assignment) to specify a telephone to ring when a Master Hunt
Number specified in Memory Block 4-14 (Intercom Master Hunt
Number Selection) is busy.
When CNF is set for two, four-party conferences, ports 1~4 can be
set to the same Master Hunt Group, and ports 5~8 can be set to a
different Master Hunt Group using Memory Blocks 4-14 (Intercom
Master Hunt Number Selection) and 4-15 (Intercom Master Hunt
Number Forward Assignment). This allows two different Pilot
Numbers for each conference.
- OR -
If only one Pilot number is needed, put all eight ports in one hunt
group using Memory Block 4-15 (Intercom Master Hunt Number
Forward Assignment). When the password is entered, the
conference selected is the conference you enter.
Use Memory Block 3-42 (DIT Assignment) to set DIT assignment to
a Master Hunt Group.
Use Memory Block 3-43 (ANA Assignment) to set ANA assignment
to a Master Hunt Group.
Restrictions:
The supervisor must perform the Setting Procedures before the
conference Bridge can be used.
Up to 16 analog Voice Mail ports are available. The CNF(8)-U10
ETU reduces this number by eight.
Each CNF(8)-U10 ETU reduces the number of stations and CAR
keys by eight.
General:
The CNF(8)-U10 ETU can be used with any version of software on
the Electra Elite 48 or 192 system.