Electra Elite Issue 6
Features and Specifications Manual A - 49
Use Memory Block 1-4-09 (Automated Attendant PBR Start Time
Selection) to specify whether the PBR can receive DTMF signaling
while the Automated Attendant is sending the message (default: FR)
or after the message is finished (AF).
Use Memory Block 1-4-11 (Automated Attendant Message Day/Night
Mode Selection) to assign the Day/Night/Weekend mode greeting
messages to each Automated Attendant position.
Use Memory Block 1-4-13 (Automated Attendant Answer Delay Time
Assignment) to set the answering time (default: 4 seconds) between
when the incoming CO/PBX call rings and when it is answered. This
time affects the Day/Night/Weekend mode settings per Automated
Attendant.
Use Memory Block 1-4-16 (Automated Attendant Message Repeat
Selection) to assign the number of times a greeting message is
repeated (default: 1).
Use Memory Block 1-8-07 [Class 0f Service (Attendant) Feature
Selection 1] Page 1 LK8 to Allow (default: LED On) or Deny (LED Off)
Attendant Positions to set/reset the Automated Attendant per trunk.
Use Memory Block 1-8-08 [Class 0f Service (Station) Feature
Selection 2] Page 2 LK6 to Allow (default: LED On) or Deny (LED
Off) a station to record, verify, or erase an Automated Attendant
message.
Use Memory Block 3-05 (Trunk Incoming Answer Mode Selection) to
assign Automated Attendant per CO/PBX line.
Use Memory Block 3-65 (Hold Tone Automated Attendant Selection)
to specify the message to be played to an extension or DID trunk on
an incoming call. System Software S5000 is required.
Use Memory Block 4-58 (Automated Attendant Selection for DID) to
specify the message for DID calls.
Use Memory Block 7-1 (Card Interface Slot Assignment) to specify
the VRS(4)-U10 ETU.
Restrictions:
CPUB( )-U10 ETU/MBD-U10 Unit PBR circuits are used for this
feature. The CPUB( )-U10 ETU for Electra Elite 192 system or
MBD-U10 Unit in the B48-U10 KSU for the Electra Elite 48 system
has four built-in PBR circuits that can be programmed for use with
the Automated Attendant, DISA feature, or Single Line Telephones.
When all four circuits are set for AA/DISA using Memory Block
1-8-01 (SLT or Automated Attendant/DISA to CPU PBR Selection), a
PBR ETU must be installed for Single Line Telephone use.
Automatic Trunk-to-Trunk Transfer and Automated Attendant cannot

Table of Contents