Newtec Proprietary
Confidentiality: Unrestricted
R3.2_v1.0
217/387
Feature Descriptions
MDM9000 Satellite Modem
Parameter Value Description
Maximum power
step down
dBm/100ms
Typically set this
value to 0.5 dBm
/100 ms.
The step down value defines how fast the power decrease
is done. How much dBm is removed per second by the
controller.
This should be faster than the power step up.
Again to avoid violating the PEB. (Refer to the figure
below.)
Typically set this value to 0.5 dBm/100 ms.
The max power step down should be
larger than the max power step up.
Modulator IP
Address
x.x.x.x/xx
Enter the MGMT modulator IP Address when the AUPC
controller resides on another device than the MDM9000
(for example the NOP1760).
The IP address is needed to setup IP connectivity between
the controller (for example on the NOP1760) and the
MDM. This to exchange the AUPC messages.
Reference
Terminal
One terminal serves as the reference AUPC terminal in
the network.
This terminal is configured with its terminal ID in the AUPC
controller.
(Refer to the following figure)
For example: use Terminal Id2 as reference terminal.