7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
Boot options
with all ports configured in network mode. The user can modify the port mode to access after system boot
up, but the software does not allow the mode to be set to access-uplink. The software allows the user to
configure services to use only either access SAPs or MPLS-based SDPs, but not access uplink SAPs. This
mode is supported on the 7210 SAS-T.
Note:
Ensure that service entities related to MPLS mode are not enabled when the device is configured
in access-uplink mode and vice-versa. The system does not enforce this.
Default
network
Parameters
access-uplink
Keyword to allow for configuration of the port in access-uplink mode and usage of access-
uplink SAPs for service configuration
network
Keyword to allow for configuration of the port in network mode and usage of network IP
interfaces and MPLS based SDPs for service configuration.
ping-address
Syntax
ping-address ip-address
no ping-address
Context
bof
Platforms
7210 SAS-Mxp, 7210 SAS-Sx/S 1/10GE, 7210 SAS-Sx 10/100GE, 7210 SAS-T (network mode and
access-uplink mode)
Description
This command configures the IP address used for a ping-test after the system boots.
The no form of this command removes the ping-address configuration. Setting a value of 0 also removes
the ping-address configuration.
Parameters
ip-address
Specifies an IPv4 IP address in the form a.b.c.d, for example, 10.1.2.10.
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.
192