alarm-contact-in-power
Syntax
alarm-contact-in-power {on | off}
Context
config>system
Platforms
7210 SAS-T (network and access-uplink), 7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description
This command allows the user to enable a supply of +24V power to the alarm input. With this feature,
users can use the power supplied through the alarm input pin to supply power to the external sensor
devices, and Equipment cabinet door sensors, and so on connected to the alarm input, instead of using an
external power source for the external sensor devices.
If the users want to use an external power source, they disable the supply of power to the alarm input pin
by using this command. By default, power is not supplied to the alarm input pin
Note:
Read the 7210 SAS device specific Installation Guides for a description of how to connect the
external sensor devices to use this capability.
Default
off
Parameters
on
Keyword to turn on power to the alarm input pin.
off
Keyword to turn off power to the alarm input pin.