7210 SAS-MXP, R6, R12, S, SX, T BASIC SYSTEM
CONFIGURATION GUIDE RELEASE 22.9.R1
System management
Description
Commands in this context configure one of four available alarm contact input pins.
Parameters
alarm-contact-input-id
Specifies the alarm contact input pin.
Values 1 to 4 (7210 SAS-T and 7210 SAS-Mxp)
Values 1 to 3 (7210 SAS-R6 and 7210 SAS-R12)
alarm-output-severity
Syntax
[no] alarm-output-severity {critical | major | minor | none}
Context
config>system>alarm-contact-input
Platforms
7210 SAS-T (network and access-uplink), 7210 SAS-Mxp, 7210 SAS-R6 and 7210 SAS-R12
Description
This command allows the user to relay alarms from the alarm-contact input to the alarm-contact output by
associating an appropriate alarm-contact output with the alarm-contact input. The system generates or
clears the alarm-contact output when it triggers or clears the alarm for the associated alarm-contact input.
If multiple alarm-contact input pins share an alarm-contact output, the system generates the alarm-contact
output even if any one of the alarm-contact input is triggered and the system clears alarm-contact output
only when all the alarm-contact input pins are cleared.
The severity parameter configured by the user determines the appropriate alarm-contact output to be used
for generation and clearing the alarm.
Note:
The system relays the alarm-contact input to the appropriate alarm-contact output only if the
alarm-contact output is available on the platform.
Default
major
Parameters
critical
Specifies that a critical alarm output is generated or cleared.
major
Specifies that a major alarm output is generated or cleared.
3HE 18197 AAAB TQZZA
© 2022 Nokia.
Use subject to Terms available at: www.nokia.com/terms/.