3.7 Installing the Charging Station
Figure 3-68. Power Supply Box Dimensions, (A) Top View, (B)Back View, (C) Wall Mount Holes,
(D) Bottom View, (E)Floor Mount Holes, and (F) Side View (units are in mm)
Per relevant safety standards the working space around the power supply box shall allow for:
l
at least 90 degrees clearance for the electrician access box door and the main electrical
compartment door to swing open.
l
at least 1 meter of clear space in front of the electrician access box and main electrical
compartment. This distance is measured from the face of the electrician access box door
and the main electrical compartment door.
Charging Station Environmental Requirements
l
Ambient temperature range:5 to 40°C
l
Humidity:5% to 95%, non-condensing
l
Power supply box IP rating: IP20
l
Docking target IP rating: IP20
NOTE: The IPrating for the copper charging pads is IP10. Do not expose
them to liquid.