Chapter 3: Setup
Docking Target Installation
You can mount the docking target to the wall or to the floor, using OMRON-supplied mount-
ing brackets. The docking target ships with the mounting brackets un-attached. If you cannot
secure the wall brackets to a structural framing member with screws, use heavy-duty toggle
(butterfly) bolts in drywall. Do not use drywall plugs or anchors.
The docking target power connector allows for horizontal and vertical connection of the power
cord. Follow these instructions to change the orientation of the docking target power connector:
1.
Remove four M6 screws ((B) in the following figure) attaching the power connector
cover ((C) in the following figure), and the power connector ((A) in the following figure)
to the docking target.
2.
Then, remove the power connector and the cover completely.
3.
Position the power connector in the desired orientation, and ensure that the power con-
nector mounting holes are well aligned with the docking target mounting holes ((D) in
the following figure).
Figure 3-71. Repositioning the Docking Target Power Connector
Callout Description Callout Description
A Power connector C Power connector cover
B M6 screws D Docking target mounting holes
4.
Once the power connector mounting holes are well aligned with the docking target
mounting holes, place the power connector cover over the power connector and screw
them to the docking target.
31500-000 Rev A HD-1500 Platform User's Manual 120