227 HD-1500 Platform User's Manual 31500-000 Rev A
8.5 Cleaning
Table 8-2. Charging Station Cleaning
Item Period
Power supply box cooling duct 6 months/ as
needed
Docking target 3 months
Docking target charging contacts 3 months
Power supply box cooling duct
The cooling duct (displayed in the following figure) must be cleaned every 6 months or after
2,000 charge cycles. This is to ensure that the airflow from the inner duct does not get trapped
by lint or dust.
Use compressed air or vacuum to remove lint, dust or buildup from the top and bottom air
vents. The bottom air vent ((B) in the following figure) is where most debris build up.
A
B
Figure 8-9. Cooling Duct, (A) Top Air Vent, and (B) Bottom Air Vent
Docking Target
Clean the docking target (excluding the charging contacts) using a soft cloth with isopropyl
alcohol and wipe thoroughly.