Fig 6.66 Memory Allocations
nCreating
a
New
Project
and
Protocol
Use
the
following
procedure
to
create
a
new
project
and
protocol.
1. Select
New
from
File
in
the
Menu
Bar
or
click
on
the
New
icon
with
the
left
button
of
the
mouse
to
create
a
new
project.
2. If
CX-Protocol
is
used,
set
the
PC
name,
PC
model,
and
network
type
according
to
the
actual
conditions.
The
network
type
refers
to
the
type
of
the
network
conected
to
the
Support
Software
and
it
does
not
refer
to
the
communications
configuration
between
the
Programmable
Controller
and
the
SYSDRIVE
RV.
The
above
settings
will
not
be
displayed
if
the
PST
is
used.
3. Double-click
on
New
Project
with
the
left
button
of
the
mouse
to
display
Protocol
List.
4. Click
on
Protocol
List
with
the
left
button
of
the
mouse
and
click
on
a
blank
space
with
the
right
button
of
the
mouse.
5. Select
Create
Protocol.
nCreating
a
Sequence
Use
the
following
procedure
to
create
a
new
sequence.
1. Click
on
New
Protocol
with
the
left
button
of
the
mouse.
Then
click
on
a
blank
space
with
the
right
button
of
the
mouse.
2. Select
Create
Communication
Sequence.
The
following
table
will
appear.
Set
the
parameters
related
to
the
sequence
in
the
table.
SYSMAC C200HX/HG/HE or CQM1H Programmable Controllers
PMCR
SYSDRIVE
3G3RV
C
S
D
Communications
Board
Protocol macro function
Word Data
S
S
1
S
2
S
3
S
4
S
5
S
6
S
7
S
8
S
9
S
10
D
D
1
D
2
D
3
No. of Slaves 0003
First Slave address 0001
RUN command to Slave 1
Frequency reference to Slave 1
Second Slave address
0002
RUN command to Slave 2
Frequency reference to Slave 2
Third Slave address
0003
RUN command to Slave 3
Frequency reference to Slave 3
Slave 1 Inverter status
Slave 2 Inverter status
Slave 3 Inverter status
C: Control data (See note.)
15 12 11 0
Communications
port
1: Port A
2: Port B
Sequence No.
000 to 999
BCD
Note Control data for the SYSMAC
C200HX/HG/HE is indicated. The SYSMAC
CS1 Series uses different control data.
RS-422A
/485
No. of data items sent in accordance with
PMCR instruction 000B
No. of data items received in accordance with
PMCR instruction 0003