FP2/FP2SHOverview
1 14
1.2 Unit Types and Combinations
Type Part number Current con-
sumption at
5V DC (mA)
Intelligent
it
C.C.U. FP2CCU 60 or less
Intelligent
unit
S-LINK unit FP2SL2 130 or less
Multi-wire link unit FP2MW 220 or less
Remote I/O Slave Unit FP2RMS 150 or less
ETLAN unit FP2ET1 670 or less
MEWNETVE Link unit FP2VE 670 or less
FNS unit
FNS unit FP2FNS 55 or less
FNS
unit
FPFNS
Bl k
PROFIBUS AFPNAB6200 230 or less
FP FNS
Block
Device Net AFPNAB6201 65 or less
CAN open AFPNAB6218 65 or less
FMU unit
PROFIBUS FP2DPV1M 450 or less
FMU
unit
Device Net FP2DEVM 150 or less
CAN open FP2CANM 450 or less
Table of current consumption at 24V DC
Type Part number Current consumption at
24V DC (mA)
Input unit DC input 16-point terminal type, 12 to 24V DC FP2X16D2 8 or less per one point
put
ut
C
put
32-point connector type, 24V DC FP2X32D2 4.3 or less per one point
64-point connector type, 24V DC FP2X64D2 4.3 or less per one point
Output unit Relay output 6-point terminal type FP2Y6R 70 or less
Output
ut
eay
output
16-point terminal type FP2Y16R 160 or less
Transistor
tt
16-point terminal NPN type FP2Y16T 120 or less
a s sto
output
32-point connector NPN type FP2Y32T 140 or less
64-point connector NPN type FP2Y64T 250 or less
16-point terminal PNP type FP2Y16P 70 or less
32-point connector PNP type FP2Y32P 150 or less
64-point connector PNP type FP2Y64P 270 or less
I/O mixed unit 32-point 24V DC input/32-point connector NPN
tt
t
FP2XY64D2T,
FP2 XY64D7T
Input: 4.3 or less per one point
/O
ed
ut
3pot
C
put/3 po t
co ecto
output type
6
,
FP2XY64D7T
Output: 120 or less
32-point 24V DC input/32-point connector PNP
output type
FP2XY64D2P,
FP2XY64D7P
Input: 4.3 or less per one point
output
type
FP2 XY64D7P
Output: 130 or less
Notes
The input unit displays the current flowing to the internal cir-
cuit. The other units display the current value required to drive
the internal circuit. This value does not include the load cur-
rent of the output unit.
Refer to the manual of the particular unit you are using to
confirm the current consumed at 24V by the S-LINK units,
Positioning units, Highspeed counter units and Pulse I/O
units.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic fp2/fp2sh and is the answer not in the manual?

Panasonic fp2/fp2sh Specifications

General IconGeneral
BrandPanasonic
Modelfp2/fp2sh
CategoryController
LanguageEnglish

Related product manuals