EasyManuals Logo

SICK microScan3 Pro I/O User Manual

SICK microScan3 Pro I/O
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
Reading and transmitting values
If t
he values in the project and the values in the device differ, you can read the values
out from the device and adopt them in the project. Alternatively, you can transmit
values from the project to the device.
b
Click on Read from device.
The values are read from the device and adopted in the project.
b
Click on Transfer to device.
The values from the project are transmitted to the device.
If the device has already been configured, the entire configuration will be transfer‐
red from the project to the device with the IP settings.
7.5 Reading configuration
Overview
A
t the left, you see the values configured in the project for the device. If the device is
connected, you see the values saved in the device at the right.
If the values in the project and the values in the device differ, you can read the values
out from the device and adopt them in the project.
Approach
b
Clic
k on Read from device.
The values are read from the device and adopted in the project.
Complementary information
Configuration:
Name
If a number of devices are used in an application or in a project, a unique device
name he
lps to tell the individual devices apart.
Chec
ksums
A checksum is used as a unique identification for a configuration. Using the
c
hecksum, it is possible to work out whether a setup was changed or whether two
devices have the same configuration.
The checksum of the configuration in the project may not match the checksum
in the device, for example if a field geometry has been modified, but not yet
transmitted to the device.
7 CONFIGURATION
106
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector