e sure that the safety laser scanner’s field of view is not restricted.
b
Make sure that there are not mirrors or other very reflective objects in the protec‐
tive field.
b
Make sure that no small objects (e.g. cables) are in the protective field, even if the
safety outputs do not switch to the OFF state as a result.
b
Mount the safety laser scanner so that the status indicators are clearly visible.
b
Mount the safety laser scanner so that you can plug in and pull out the system
plug.
b
Take appropriate measures for vibration damping if vibration and shock specifica‐
tions exceed the values and test conditions specified in the data sheet, see "Data
sheet", page 178.
b
For machines that vibrate heavily, use thread-locking compounds to prevent the
possibility of fixing screws coming loose unintentionally.
b
Make sure that the safety laser scanner is aligned correctly, even during mount‐
ing: if the safety laser scanner is intended to monitor an area of 270° on a corner,
the safety laser scanner may be mounted rotated by a maximum of 2.5° about the
vertical axis.
b
Location of the scan plane: see "Dimensional drawings", page 205.
b
Take account of the tightening torque for the fixing screws:
°
M5 at rear/at side = 4.5 Nm … 5.0 Nm
°
M4 at rear/at side = 2.2 Nm … 2.5 Nm
Higher tightening torques may damage the thread. Lower tightening torques do
no
t offer sufficient protection against slipping of the safety laser scanner due to
vibrations, for example.
5.3.1 Changing position of the system plug
Overview
The system plug is installed at the bottom or rear when the safety laser scanner is
delivered. You can change the position of the system plug if needed.
Prerequisites
T
ool required:
TX20 Torx wrench
Approach
1.
Loosen the screws of the system plug.
2. Carefully remove the system plug from the safety laser scanner.
MOUNTING 5
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
87
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector

Related product manuals