50
60
120
0 100 150
Z
F
B
F
[mm]
[mm]
Figure 35: Minimum supplement for lack of ground clearance
B
F
ground clearance in mm
Z
F
supplement for lack of ground clearance in mm
Calculation example for the protective field length S
L
S
L
= S
A
+ T
Z + Z
R
+ Z
F
+ Z
B
where:
S
L
= protective field length in millimeters (mm)
S
A
= stopping distance in millimeters (mm)
TZ = tolerance range of the safety laser scanner, see "Data sheet", page 178
Z
R
= supplement for reflection-based measurement errors in millimeters (mm)
Z
F
= supplement for lack of ground clearance of the vehicle in millimeters (mm)
Z
B
= supplement for the decreasing braking force of the vehicle, from the vehicle
documentation, in millimeters (mm)
Stopping distance S
A
T
he stopping distance comprises the vehicle’s braking distance and the distance cov‐
ered during the safety laser scanner’s response time and the vehicle control’s response
time (including signal propagation time).
NOTE
A v
ehicle’s braking distance does not increase linearly with increasing speed, but rather
in a squared relationship.
4 PROJECT PLANNING
50
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)