EasyManuals Logo

SICK microScan3 Pro I/O User Manual

SICK microScan3 Pro I/O
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Mobile hazardous area protection
Mobile ha
zardous area protection is suitable for AGVs (automated guided vehicles),
cranes, and forklift trucks to protect people when vehicles are moving or docking at a
fixed station.
The safety laser scanner monitors the area in the direction of travel and stops the
vehicle as soon as an object is located in the protective field.
Figure 16: Mobile hazardous area protection: detection of a person when a vehicle approaches
3 P
RODUCT DESCRIPTION
24
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector