SICK microScan3 Pro I/O User Manual

SICK microScan3 Pro I/O
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Display reference contour field
Y
ou determine whether the reference contour field is displayed.
Drawing surface
Y
ou can use a Cartesian or a polar coordinates system and select the colors for the grid
and the drawing area.
b
Select the Cartesian option.
The coordinates system is shown as a Cartesian coordinates system.
b
Select the Polar option.
The coordinates system is shown as a polar coordinates system.
b
Select Color of the grid.
The field editor’s grid is displayed in the chosen color.
b
Select Color of the drawing surface.
The field editor’s drawing area is displayed in the chosen color.
7.11.6 Editing fields using coordinates
You can use coordinates to edit fields. Depending on the form on which a field is
ba
sed, the appropriate input fields are displayed. The example shows a dialog box for a
rectangle.
7 C
ONFIGURATION
124
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector