A typical application is the use of a protective field with one or more warning fields: if a
v
ehicle approaches a person, a warning field triggers an optical or acoustic signal. If the
person does not react to this and the vehicle continues to approach, the safety laser
scanner detects an object in the protective field and switches the associated safety
outputs to the OFF state. The vehicle stops before it reaches the person.
Figure 9: Field set, consisting of one protective field (red) and 2 warning fields (orange and
y
ellow)
3.3.6 Monitoring case
A monitoring case signals the machine status to the safety laser scanner. The safety
la
ser scanner activates the field set, which is assigned to the monitoring case and
therefore a particular machine status.
If a machine, e.g., has various operational statuses, a monitoring case can be assigned
to each operational status. The safety laser scanner receives a defined signal for the
current operational status via the control inputs or the safety-related network. If there
is a change of signal, the safety laser scanner switches from one monitoring case to
the monitoring case that is assigned to the new signal (as well as the new operational
status). Generally, one field set is assigned to each monitoring case.
3 P
RODUCT DESCRIPTION
20
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector