4
Working range
5
Device catalog
6
Task list and notes
7.2.4 User groups
Overview
T
he devices contain a hierarchy of user groups that regulate access to the devices.
For certain actions (e.g., transferring a configuration to the device), you are requested
to log onto the device with the respective user group.
Important information
NOTICE
W
hen you log into a device, the configuration software stores the password so that you
do not need to re-enter it for other configuration steps.
If you do not change any other settings in the login dialog, the password is deleted as
soon as you exit the configuration software, or log out in the main window or Device
window.
If you enable the Temporarily store password for login on additional devices. function, the
password will be retained even if you log out in the device window only.
If you leave the computer unattended, you must log off to prevent unwanted access to
the device.
Table 12: User groups
User group Password Authorization
Operator No password required. Anyone can
lo
g on as a machine operator.
Ma
y read configuration from the
device.
Maintenance
per
sonnel
Deactivated ex-works, i.e. it is not
initially possible to log on as a
maintenance technician. The user
group can be activated by the user
group administrator and provided
with a password.
Ma
y read configuration from the
device.
May transmit verified configura‐
tion to the device.
Change own password allowed.
Authorized client Deactivated ex-works, i.e. it is
no
t initially possible to log on as
an authorized customer. The user
group can be activated by the user
group administrator and provided
with a password.
Ma
y read configuration from the
device.
May transmit verified and
unverified configuration to the
device.
May verify configuration.
Resetting the safety function
and communication settings to
factory defaults is allowed.
Change own password allowed.
Changing the password of the
Maintenance personnel user group
is allowed.
CONFIGURATION 7
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
99
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector