7.6 Identification
Overview
Figure 67: Identification
1
Parameters for the project and the device
In the Ident
ification dialog box, you can optionally enter names and information to
uniquely identify the application, project, and devices.
Device name
If a number of safety laser scanners are used in an application or in a project, a unique
device name helps to tell the individual devices apart.
b
Give each device a unique device name.
Project name
T
he project name is used to identify an entire project. The same project name should
be chosen for all devices in the project.
b
Enter a project name.
Application name
T
he application name can be the same for a number of devices in the project. It
highlights that these devices realize an application together, by responding to one
another for example.
b
Enter an application name.
CONFIGURATION 7
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
107
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector