15 Spare parts
15.1 Safety laser scanner without system plug
Table 55: Safety laser scanner without system plug
Spare part for Type code Part number
Device Part number Protective field
ran
ge
microScan3 Pro I/O 1110035 ≤ 4.0 m MICS3-CCAZ40AA1 1110034
microScan3 Pro I/O 1110033 ≤ 5.5 m MICS3-CCAZ55AA1 1110032
microScan3 Pro I/O 1110037 ≤ 9.0 m MICS3-CCAZ90AA1 1110036
15.2 System plug
Table 56: System plug
Spare part for Connection type Type code Part number
Device Part number
microScan3 Pro I/O 1110033,
1110035,
1110037
M12 plug connector MICSX-CAAAMDMD1 2115434
15.3 Additional spare parts
Table 57: Additional spare parts
Part Part number
Optics cover (with seal and screws) 2073673
Cover plate, 91.8 mm × 42.8 mm (with screws) 2075877
SPARE PARTS 15
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
207
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector

Related product manuals