Available data:
•
St
atus of safety function
•
Status sleep mode
•
Contamination warning
•
Contamination error
•
Reference contour monitoring
•
Manipulation
•
Cut-off path (safety-oriented)
•
Cut-off path (Not safety-related)
•
Current monitoring case
•
Application error
•
Device error
Assembly 120: output of the device, input of the control (not safety-related)
•
CIP
•
U
pdate cycle: 5 ms (or a multiple of this, depending on RPI)
•
Length: 12 bytes
•
For automation and diagnostic tasks without safety implication
Available data:
•
Status of safety function
•
Status sleep mode
•
Contamination warning
•
Contamination error
•
Reference contour monitoring
•
Manipulation
•
Cut-off path (Not safety-related)
•
Reset required
•
Current monitoring case
•
Application error
•
Device error
Assembly 121: Output of the device, input of the controller (not safety-related)
•
CIP
•
U
pdate cycle: 5 ms (or a multiple of this, depending on RPI)
•
Length: 8 bytes
•
For automation and diagnostic tasks without safety implication
Available data:
•
Control input
•
Speed at dynamic control input
4.5.4 Host-guest group
Overview
Y
ou can connect one microScan3 Pro I/O to up to 3 other microScan3 EFI-pro or
microScan3 Pro I/O via EFI-pro.
The microScan3 Pro I/O takes over the role of the host. The other microScan3 are
guest devices.
In a host-guest group, all devices can use the local inputs and outputs of the host.
Prerequisites
•
T
he host is a microScan3 Pro I/O.
•
Each guest is a microScan3 EFI-pro or a microScan3 Pro I/O.
•
All devices are on the same network.
•
All devices have the same SNN.
4 P
ROJECT PLANNING
78
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice