EasyManuals Logo

SICK microScan3 Pro I/O User Manual

SICK microScan3 Pro I/O
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
Available data:
Cut
-off path (safety-oriented)
Cut-off path (Not safety-related)
Assembly 110: output of the device, input of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Available data:
Status of safety function
Status sleep mode
Contamination warning
Contamination error
Reference contour monitoring
Manipulation
Cut-off path (safety-oriented)
Cut-off path (Not safety-related)
Current monitoring case
Reset required
Application error
Device error
Assembly 113: output of the device, input of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 16 bytes
Available data:
Status of safety function
Status sleep mode
Contamination warning
Contamination error
Reference contour monitoring
Manipulation
Cut-off path (safety-oriented)
Cut-off path (Not safety-related)
Current monitoring case
Reset required
Application error
Device error
Assembly 114: Output of the device, input of the guest device
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Local inputs of this device can be used as network inputs of another EFI-pro
device.
Available data:
Control input
Speed at dynamic control input
Assembly 115: Output of the device, input of the controller
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 16 bytes
PROJECT PLANNING 4
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
77
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector