Assembly 103: input of the device, output of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 16 bytes
Switching between monitoring cases via monitoring case number
Available data:
Start safety function
Stop Event history
Activate sleep mode
Monitoring case number
Reset
Restarting safety function and connections
Restart device completely
Assembly 104: Input of the device, output of the controller
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Switching between monitoring cases via dual-channel information, like with devi‐
ces with locally-connected static control inputs.
Monitoring case switching via dual-channel speed information, similar to devices
with locally connected incremental encoders
Available data:
Monitoring case switching
Control input
Speed at dynamic control input
Assembly 105: input of the device, output of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Switching between monitoring cases via dual-channel information, like with devi‐
ces with locally-connected static control inputs.
Monitoring case switching via safe speed information
Available data:
Start safety function
Monitoring case switching
Stop Event history
Activate sleep mode
Control input
Safe speed
Reset
Restarting safety function and connections
Restart device completely
Assembly 106, Assembly 107, Assembly 108: Input of the device, output of the guest
de
vice
CIP Safety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Local outputs of this device can be switched from network outputs of another
EFI-pro device.
4 P
ROJECT PLANNING
76
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector