If you do not specify a subsequent monitoring case for a monitoring case, then any
monit
oring case may follow.
Individual steps
You define individually for each monitoring case which one or two monitoring cases may
follow.
If you do not specify a subsequent monitoring case for a monitoring case, then any
monitoring case may follow.
Complementary information
Y
ou can use the changeover order as an additional check of your control unit. For exam‐
ple, deviations of a vehicle from the route or a plant from the prescribed production
process can be detected.
7.14.2 Several monitoring case tables
Certain variants of the safety laser scanner support multiple simultaneous monitoring
c
ase tables. For example, you can use a monitoring case table to switch between
different monitoring cases with different field sets. At the same time, you can use
another monitoring case table to keep a monitoring case always active with a particular
field set.
Even if you use several monitoring case tables, each shutdown path is assigned to only
one monitoring case table.
If you use several monitoring case tables, one monitoring case must be active in
each monitoring case table at all times. As long as no monitoring case is active in a
monitoring case table after the start, all outputs remain in the OFF state and the device
displays Waiting for inputs. If no monitoring case is active in a monitoring case table
during operation, all outputs switch to the OFF state and the device displays a fault.
7.14.3 Settings for monitoring cases
Name
Ent
er a name which is as descriptive as possible for the monitoring case in the Name
field. If you create a lot of monitoring cases, you should consider a naming concept that
makes it possible to identify the monitoring cases easily (for example right cornering,
left cornering).
Sleep mode
If y
ou activate this option, the safety laser scanner changes to the sleep mode as soon
as the input conditions for this monitoring case exist.
7.14.4 Input condition
For each monitoring case, choose the input conditions for which the monitoring case
w
ill be activated.
b
Activate the combination of inputs for each monitoring case.
The relevant monitoring case is activated for exactly this combination.
Combinations which are invalid or already assigned are marked.
CONFIGURATION 7
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
137
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector