EasyManuals Logo

SICK microScan3 Pro I/O User Manual

SICK microScan3 Pro I/O
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Contents
1 About this document........................................................................ 8
1.1 Function of this document....................................................................... 8
1.2 Scope......................................................................................................... 8
1.3 Target groups of these operating instructions........................................ 8
1.4 Further information................................................................................... 8
1.5 Symbols and document conventions...................................................... 9
2 Safety information............................................................................ 10
2.1 General safety notes................................................................................ 10
2.2 Intended use............................................................................................. 11
2.3 Inappropriate use..................................................................................... 11
2.4 Cybersecurity............................................................................................ 12
2.5 Requirements for the qualification of personnel.................................... 12
3 Product description........................................................................... 13
3.1 Device overview........................................................................................ 13
3.2 Setup and function................................................................................... 14
3.3 Product characteristics............................................................................ 15
3.3.1 Variants.................................................................................... 15
3.3.2 Connections............................................................................. 16
3.3.3 System plug.............................................................................. 16
3.3.4 Field types................................................................................ 16
3.3.5 Field set.................................................................................... 19
3.3.6 Monitoring case....................................................................... 20
3.3.7 Simultaneous monitoring........................................................ 21
3.4 Example applications............................................................................... 22
4 Project planning................................................................................ 25
4.1 Manufacturer of the machine.................................................................. 25
4.2 Operator of the machine.......................................................................... 25
4.3 Assembly................................................................................................... 26
4.3.1 Protection from influences...................................................... 27
4.3.2 Preventing unprotected areas................................................. 28
4.3.3 Response time of the safety laser scanner........................... 30
4.3.4 Reference contour monitoring................................................ 30
4.3.5 Monitoring case switching time.............................................. 32
4.3.6 Hazardous area protection...................................................... 34
4.3.7 Hazardous point protection..................................................... 41
4.3.8 Access protection.................................................................... 44
4.3.9 Mobile hazardous area protection.......................................... 47
4.3.10 Mobile protection in narrow aisles......................................... 53
4.4 Integrating the equipment into the electrical control............................. 61
4.4.1 Electromagnetic compatibility................................................. 63
4.4.2 Voltage supply.......................................................................... 64
CONTENTS
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
3
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector