EasyManua.ls Logo

SICK microScan3 Pro I/O - Network settings; EFI-pro

SICK microScan3 Pro I/O
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.4 Network settings
7.4.1 EFI-pro
Overview
Figure 66: Network settings: EFI-pro
1
Values in the project
2
Values in the device
3
Buttons to read or transmit values
NOTE
If a de
vice has already been configured, the entire configuration will be transmitted
from the project to the device when the IP settings are changed. The configuration of
the control may also be invalid.
b
Before changing the IP settings: Read the configuration from the device using
Safety Designer and save if necessary.
IP address:
In or
der to enable communication between the device and the SICK safety controller or
a computer, please enter the IP settings here. The IP address for the device must be
unique in the network and it must be in the same subnet as the IP address for the SICK
safety controller.
b
Enter IP adress, Subnet and, if applicable, Router.
CONFIGURATION 7
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
105
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Related product manuals