7.4 Network settings
7.4.1 EFI-pro
Overview
Figure 66: Network settings: EFI-pro
1
Values in the project
2
Values in the device
3
Buttons to read or transmit values
NOTE
If a de
vice has already been configured, the entire configuration will be transmitted
from the project to the device when the IP settings are changed. The configuration of
the control may also be invalid.
b
Before changing the IP settings: Read the configuration from the device using
Safety Designer and save if necessary.
IP address:
In or
der to enable communication between the device and the SICK safety controller or
a computer, please enter the IP settings here. The IP address for the device must be
unique in the network and it must be in the same subnet as the IP address for the SICK
safety controller.
b
Enter IP adress, Subnet and, if applicable, Router.
CONFIGURATION 7
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
105
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector