A static control input consists of 2 channels. To switch correctly, one channel must
be s
witched inversely to the other.
1-of
-n
In the 1-of-n evaluation, use the channels of the control inputs individually. At any
t
ime, exactly one channel must have logic value 1.
C
ase number
For certain assemblies, the monitoring cases are activated by their number.
Speed
Y
ou specify which source is used for the speed. If you use 2 non-safe speed sources,
also specify the tolerated deviation between the 2 signals.
Other functions
Y
ou specify which source is used to restart the device, put it into sleep mode, or pause
the event history.
Behavior after connection gets lost
Y
ou can configure the way in which the device behaves when secure communication
is reestablished in the network after an interruption:
Manual start through “Restart safety function” action
After canceling secure communication, the safety function is stopped and the
de
vice reports an application error. Once the connection is established again, you
must send the command Restart safety function to the device via the assembly or via
Safety Designer.
Aut
omatic start after connection
After aborting the safe communication, the safety laser scanner signals to W
ait for
inputs. As soon as the connection has been reestablished, the device automatically
switches to the current monitoring case. No additional command is required.
Local outputs
Safety Designer shows which local outputs are configured.
Remote switching
A hos
t in a host-guest group can use the monitoring results of the guest devices to
switch the local outputs. The local outputs then map both the local monitoring results
and the monitoring results of the guest devices.
Under Remote switching, you can set whether the monitoring results of the guest devices
are used to switch the local outputs. In addition, you set which local output is switched
for each assembly and each cut-off path of the guest devices.
Restart behavior
Y
ou define whether the internal restart interlock of the network outputs is used.
If necessary, specify which assembly is used for resetting.
Available network outputs
S
afety Designer displays which network outputs are available.
7 C
ONFIGURATION
130
O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O 8025424/1ELL/2022-01-21 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector