T
he menu provides access to the following areas:
Device info
Diagnostics
Device restart
Settings
Approach
b Pr
ess the OK pushbutton 4 twice in succession to call up the menu.
b Use the arrow buttons 1, 2 to change to the desired menu item.
b Confirm the desired menu item using the OK pushbutton 4.
b
Use the same pushbuttons to navigate through the submenus.
b Press the Back pushbutton 3 to return to the higher-level menu item.
b Press the Back pushbutton 3 multiple times to return to the status display.
b
Do not press any pushbutton for some time so that the display returns to the
status display.
Device info
Y
ou will find information about the following subjects in the area:
Hardware: For example type code, part numbers, serial numbers, firmware versions,
functional scope of device
Configuration: For example device name, application name, checksum, date of last
configuration, functional scope of configuration
Service interfaces: Information on whether access to individual interfaces and serv‐
ices is activated or deactivated
Fieldbus: For example MAC address, IP address, subnet
Data output: For example status, destination IP address
The Functionality of the device and Functionality of the configuration show whether a configu‐
ration is compatible with the firmware version of a device. This can be important when
exchanging a device, for example.
Configuration and firmware version of a device are compatible if the following condi‐
tions are met:
The 1st place of both numbers must be identical
The 2nd place for the device must be at least as large as that for the configuration
The 3rd place does not have an effect on the compatibility
Diagnostics
Chec
k whether the safety laser scanner is being dazzled by an external light source in
the scan plane, e.g., sun, halogen light, infrared light source.
Intrusions: Position and time of the last 10 objects in a protective field that have led
to a safety output switching to the OFF state.
Messages: Error code and error type of the last 10 error messages.
Service: Currently measured contamination of the optics cover, operating hours,
number of power-up processes.
Device restart
Y
ou have the following options in the Device restart area:
Restart the safety laser scanner.
Settings
Y
ou have the following options in the Settings area:
Set the display brightness and contrast.
TROUBLESHOOTING 11
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O
167
Subject to change without notice

Table of Contents

Other manuals for SICK microScan3 Pro I/O

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK microScan3 Pro I/O and is the answer not in the manual?

SICK microScan3 Pro I/O Specifications

General IconGeneral
Scanning angle275°
Number of fields128
Dimensions102 mm x 152 mm x 106 mm
Number of safety outputs2
Number of OSSD outputs2
Scanning range5.5 m
Protective field range5.5 m
Resolution30 mm
Number of monitoring cases128
Response time60 ms
InterfacesEthernet, USB
Operating temperature+50 °C
Protection classIP65
Supply voltage24 V DC
Storage temperature+70°C
Operating voltage24 V DC (16.8 V DC ... 28.8 V DC)
Housing materialPlastic
Connection typeMale connector