Data formats and data records
SIMATIC - ET 200pro motor starter
D-32 GWA 4NEB 950 5661-02 DS 04
—20
0…7
Recovery time 60…1800 s 30 s 90 s
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
—21
0…7
Idle time 0…255 s
deactivated [0]
1s [0]
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
22…23 Pre-warning limit
value – temporal
tripping reserve
0…500 s
deactivated [0]
0.1s 0s
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
6
6…7
24
0…1
Response to over-
load – temperature
sensor
Tripping without
restart [0]
Tripping with restart
[1]
Warning [2]
—[0]
sDSSte/sDSte,
sRSSte/sRSte
—24
2…3
Reserved
7
0…2
24
4…6
Temperature sensor deactivated [0]
Thermoclick [1]
PTC Type A [2]
—[0]
sDSSte/sDSte,
sRSSte/sRSte
—24
7
Temperature sensor
monitoring
no [0]
yes [1]
—[1]
sDSSte/sDSte,
sRSSte/sRSte
—25
0…7
Lower current pre-
warning limit value
Not used
26…27 Permitted line oper-
ating current
Not used
8
0…7
28
0…7
Lower current limit 18.75%…100% 3.125% 18.75%
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
9
0…7
29
0…7
Upper current limit 50% ... 150% 3.125% 112.5%
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
—30
0…7
Blocking current 150% ... 1000% 50% 1000%
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
31 Upper current pre-
warning limit value
Not used
—32
0…3
Blocking time 1 s…5 s 0.5 s 1 s
DSe, RSe (HF);
sDSSte/sDSte,
sRSSte/sRSte
7
4…5
32
4…5
Response to supply
voltage
Switching element
missing
General fault [0]
General fault only
with On command
[1]
General warning [2]
—[0]
all starters
ET 200
pro
RPM
Byte
No.
DS 131
Byte no.
Parameters Value range
Increme
nt
Factory
setting
Relevant for
Table D-18: Data record 131device parameters (Continued)